Products · United electric
 

Conductor
HV cable cross section
HV cable structure
Remarks

  • Description
  • Specification
  • Approvals / References
  • Others

50/66(72.5)kV, 64/110(126)kV, Dry type plug-in GIS / Transformer Termination


The dry type plug-in termination is consisted of epoxy resin bushing and silicone rubber stress cone two main

separately parts; insulation stop-end, test cable bushing and transition tools are also provided with main parts.

They are suitable for SF6-gas-insulated switchgear and transformer. The bushing can be installed and tested in

advance at the switchgear manufacturer's plant, thus obviating the need for additional work with SF6-gas for cable

installation on site.

The interface dimensions conform to IEC 60859 or are agreed between the switchgear and cable system suppliers

for particular application concerned.


Selection guide

HV Dry type plug-in termination


HV Dry type plug-in terminationHV Dry type plug-in termination
HV Dry type plug-in terminationHV Dry type plug-in terminationHV Dry type plug-in termination
Plug-in terminationTest bushingLonger bushingBushingStop-end


Components configuration

•  The electrical connection and insulation parts are all inside the metal shell which is suitable for indoor and outdoor field.

    The termination is not exposed in the air thus there is no limitation for environmental condition, soilage grade or altitude.

•  The length of bushing is 470mm for 110kV and 132kV, 410mm for 66kV; a short cabe preparation length is needed and

    easy installation. If the length of bushing is 757mm, a transition tool is provided. 

•  A compact design of field control screen inside of the resin bushing and stress cone molded inside the termination body.

•  A press spring is designed for the sake of interfacial insulation strength increase between different insualtion material

   acting proportional on the stress cone to achieve a high insulation strength through a composited insulation pulg-in

   structure as an insulation entity.


Properties



HV Dry type plug-in terminationHV Dry type plug-in termination
HV Dry type plug-in terminationHV Dry type plug-in termination
HV Dry type plug-in termination




Application



HV Dry type plug-in terminationHV Dry type plug-in termination
110kV plug-in termination used in Wuhan Utility110kV GIS plug-in termination used in Jiangsu
HV Dry type plug-in terminationHV Dry type plug-in termination
110kV GIS plug-in termination used in Henan110kV GIS plug-in termination used in Chongqing
HV Dry type plug-in terminationHV Dry type plug-in termination
110kV plug-in termination used in Chongqing
110kV plug-in termination used in Guangdong




Technical data


HV Dry type plug-in termination

HV Dry type plug-in termination



Contact us immediately
Contact us immediately
  • 您的姓名:
  • *
  • E-mail:
  • *
  • 公司名称:
  • *
  • 地址:
  • *
  • 电话:
  • *
  • QQ:
  • 传真:
  • *
  • 邮政编码:
  • *
  • 留言主题:
  • *
  • 详细说明:
  • *
CONTACT
United Electric Co., Ltd. 515 Saiba Bldg. No.16, Keji North 2nd Road, Nanshan District, Shenzhen 518057, Guangdong, China.
Tel: +86 755 26419370 / 26419390           Fax: +86 755 26414580
export@ueaccessory.com
SHARING
Copyright ©2019 - 2022 United Electric Co
犀牛云提供企业云服务
X
1

QQ设置

3

SKYPE 设置

4

阿里旺旺设置

1

QQ设置

5

电话号码管理

  • 4006-971-972
6

二维码管理

  • Leave Message
999999

邮箱

CONTACT US
  • Name:
  • *
  • Phone:
  • *
  • Email:
  • *
  • Message:
  • *
We won't share your into with third parties
展开